30
Connections and settings
Event Settings
Sensor
Input Channel: Select the number of the ALARM-IN
terminal.
Sensor Type: The sensor state can be set to either N.O.
(Normally Open) or N.C. (Normally Closed).
Camera: Select the connected camera channel to the
ALARM-IN terminal.
Relay Output:
ON: Outputs the alarm (relay) signal via the RELAY-
OUT terminal.
OFF: Not used.
•
•
•
•
-
-
Motion
Channel: Select the channel to set motion detection.
Sensitivity: Set the level of sensitivity for the created
motion detection area. Sensitivity can be set from level
01 to 10 or NONE.
Relay Output:
ON: Outputs the alarm (relay) signal via the RELAY-
OUT terminal.
OFF: Not used.
Notes:
In the condition that illumination is low and the outline
of object is not clear enough to see, regardless of sen-
sitivity, Motion Event could be possible not to happen.
You must check Motion Event before setting.
Motion area setting
1. Select the desired channel in live screen mode.
2. Press OSD or click the right mouse button to display
the sub-setup menu.
3. Select [Motion] option and press ENTER.
4. Select the desired motion detection area on the
selected channel window screen.
Using the Remote control
b / B / v / V
: Moves the cell box to
another cell zone.
ENTER: Selects or cancels the motion detec-
tion area at the current cell position.
Using the Mouse
To select the area: Drag & drop a cell to the
right to select the motion detection area.
To cancel area: Drag & drop a cell point of
a selected cell area to the left to cancel the
motion detection area.
•
•
•
-
-
•
•
•
-
-
•
-
-