Installation
26 Multi type Air Conditioner
The wall you select should be strong and solid
enough to prevent vibration
1. Mount the installation plate on the wall with
type "A" screws. If mounting the unit on a con-
crete wall, use anchor bolts.
• Mount the installation plate horizontally by aligning
the centerline using a level.
2. Measure the wall and mark the centerline. It is
also important to use caution concerning the
location of the installation plate-routing of the
wiring to power outlets is through the walls typi-
cally. Drilling the hole through the wall for piping
connections must be done safely.
2. Art Coll Deluxe Type Indoor Unit
Installation Plate
Type "A" screw
Installation plate
Ø70mm
Left rear piping
Right rear piping
C
D
B
A
Ø70mm
Left rear piping
Right rear piping
B
A
D
C
Right rear piping
B
A
D
C
Installation plate
(SU)
(SZ)
(S3)
Installation plate
• Drill the piping hole with a ø70mm hole core drill.
Drill the piping hole at either the right or the left
with the hole slightly slanted to the outdoor side.
3. Drill a Hole in the Wall
5-7mm
(3/16"~5/16")
Indoor
WALL
Outdoor
A
B
C
D
SZ
35
33
156
33
(7k~9k)
SU
92
44
67
44
(11k~14k)
S3
58
3
292
3
(18k~26k)
CHASSIS
(Grade)
Distance (mm)
• For S3 chassis, the center of the unit is different
from that of the Installation plate.
Summary of Contents for L8UC100BFA0
Page 92: ...92 Multi type Air Conditioner Schematic Diagram 2 Outdoor Unit 1 L8UC100BFA0 L8UH100BFA0 ...
Page 95: ...Service Manual 95 L8UH100BFA0 L8UC100BFA0 Schematic Diagram 2 Outdoor Unit ...
Page 97: ...Service Manual 97 2 Duct Type High static BH BG BE chassis Schematic Diagram ...
Page 98: ...98 Multi type Air Conditioner Schematic Diagram Low static BT BT1 chassis ...
Page 99: ...Service Manual 99 4 way TE TF TD chasis 58 B Schematic Diagram ...
Page 100: ...100 Multi type Air Conditioner Schematic Diagram 2 Display ASSEMBLY 1 Split Type ...
Page 153: ...P No 3828A22009L October 2005 Printed in Korea ...