Installation and Operation Manual
38
3.10.2 Hold Recall
Description
When a user places a Line call on hold, a hold timer is activated. If the timer expires, the held call will recall
at the station for the I-Hold Recall time (30sec). If the call remains unanswered, the call is placed on
System Hold and the LWS-BS station also receives a recall for the Attendant Recall time (1min). If still
unanswered after the Attendant Recall time, the Line call is disconnected and the appropriate circuits are
returned to idle.
Operation
Hold Recall operation is automatic.
3.10.3 Automatic Hold
Description
While on an active Line call, the system will place the call on hold automatically if the user presses the
{Station/Line}
button.
In this case, pressing a
{Line}
button while on a Line call will place the active call on hold and access the
selected Line.
Operation
To use Automatic Hold while on an active Line call:
LWS-BS station
1.
Press the desired feature button or {
Line
} button; the active call is placed on Hold.
Conditions
1.
There is no limit on the number of calls that can be placed on Hold using Automatic Hold.
3.11 CID Blacklist
Description
The system can employ caller number to determine the routing of incoming external calls.
The system will compare the received caller number to entries in the CID Blacklist, and if a match is found,
will route the call to the Voice mail of base station or disconnect the call.
Programming
C
ONFIGURATION
Blacklist destination
– [Menu] + 3 1 1
Blacklist entry - [Menu] + 3 1 2