Page 60
2
With the type flashing, press the
DOWN
button until the LCD display
shows
Function = Dimmer
.
3
Press the
Select/Save
button.
Dimmer
flashes.
4
Press the
UP
or
DOWN
buttons until the LCD display shows
MAX
LEVEL= 100%
.
5
Press the
Select/Save
button to select the desired function.
6
Press the
UP
or
DOWN
buttons to select the desired maximum
level.
7
Press the
Select/Save
button.
8
Press the
RIGHT
or
LEFT
button to move on to another circuit
or press the
Cancel/Clear
button several times slowly to return to the
main menu.
Step 13E: Verifying Module Programming in a
Dimmer Cabinet
To determine how the modules are programmed in the dimmer cabinet, check the
module programming:
1
Make sure the powered on and in operating normally.
2
Press the
UP
button.
The LCD display shows
MENU SETUP
, with
MENU
flashing.
3
Press the
UP
button again.
The LCD display shows
MENU MODULE STATUS
.
4
Press the
SELECT
button.
The LCD display shows how the first circuit of the first dual dimmer
is programmed.
Module programming information is displayed in a two-line format, as in the
following example:
The above example indicates Module 01A, which is normally a dual dimmer, and
the A circuit of that dimmer is set to 50% of full brightness. DM indicates that it is
set up as a standard dimmer.
MOD 01A = 50% DM
INPUT=LUMANET S
Module number
Portion of dimmer set to this percent brightness
Percent of full brightness (
FL
for 100%)
Dimmer type
Whether dimmer can accept more than one
input type (blank if only assigned to one input type)
Type of signal driving this half of module
(could be
LUMANET
or
DMX512
or
ANALOG
in this case)