HUBBLE series
System Administrator’s
Manual
71
Local DIO
The Local DIO page allows you to configure the digital input (DI) and digital output (DO) of
the NVR.
Field Name
Description
Active Level
Set whether the active device level is high or low.
This can be interpreted as On or Off.
Stable Time
This is the amount of time used by the NVR to filter
out false signals which may be caused by power
surge. For example, setting the
Stable Time
to 2
seconds will require a digital input device like a
push button to be pressed for 2 seconds. If the
button is pressed only for 1 second then the DI is
not triggered.
Dwell Time
This is the amount of time when the device stays in
active level. If Dwell Time is set to 5 seconds, and if
an input device like a push button is repeatedly
pressed within 5 seconds, the NVR only accepts
interprets that signal as one input signal and not
five.