Group:
uart_i<0~(n-1)> n is uart port count
Name Value
Security
(get/set)
Description
baudrate 110
300
600
1200
2400
3600
4800
7200
9600
19200
38400
57600
115200
4/4
Set baud rate of COM port
110 => 110
300 => 300
600 => 600
1200 => 1200
2400 => 2400
3600 => 3600
4800 => 4800
7200 => 7200
9600 => 9600
19200 => 19200
38400 => 38400
57600 => 57600
115200 => 115200
databit 5
6
7
8
4/4
Data bits in a character frame
5 => 5
6 => 6
7 => 7
8 => 8
paritybit none
odd
even
4/4
For error checking
none => none
odd => odd
even => eve
stopbit 1
2
4/4
1 => 1
2 => 2
uartmode rs485
rs232
4/4
rs485 or rs232
uartreset
<boolean>
4/4
Set this flag to true to apply change of UART
configuration.
customdrvcmd_i
<0~9>
string[128]
1/4
PTZ command for custom camera.
speedlink_i
<0~4>_name
string[40] 1/4 Additional PTZ command name
speedlink_i
<0~4>_cmd
string[128] 1/4 Additional PTZ command list
ptzdriver 0~19
127 (custom)
128 (no
driver)
4/4
Which PTZ driver is used by this COM port
Group:
privacymask_c<0~(n-1)
> for n channel product
Name Value
Security
(get/set)
Description
enable
<boolean>
4/4
Enable the privacy mask
win_i<0~4>_
enable
<boolean>
4/4
Enable the privacy mask window
win_i<0~4>_
name
string[14] 4/4 The
name
of privacy mask window
win_i<0~4>_left 0 ~ 320/352 4/4
Left coordinate of window position.
win_i<0~4>_top 0 ~ 240/288 4/4
Top coordinate of window position.