Mounting and commissioning
Leuze electronic GmbH & Co. KG
CSL 505
22
Checking mounting height
Are the transmitter and receiver mounted at the same height?
Check the distance relative to the reference level (e.g. measure the distance from the floor or
from the machine table)
Checking that devices are mounted vertically
Are the devices mounted vertically?
1.
Hold a level against the front screen
Check the vertical alignment
2.
Hold a level against the side panel
Check the vertical alignment
Checking alignment of transmitter and receiver
The following steps must be performed for the transmitter
and
receiver.
Rotate the transmitter and receiver about the vertical axis until the front screens of the devices
are perfectly aligned with each other.