Product description
Leuze electronic GmbH & Co. KG
CSL 505
20
3.6.2
Operating range
The parameter
Operating range
is used to switch over to "reduced" operating range.
Operating range
Comment
0
Increased transmitter power (factory setting in parameter set 1)
1
Reduced transmitter power (factory setting in parameter set 2)
2 … 255
Disable
transmitter
deactivation
Start test with range switching option
Selectable at the input:
24 V reduced, 0 V normal
The value corresponds to a time delay
in steps of 2.56.
Example:
200 gives a time delay of 512 ms.
During the time delay, the transmitter
is deactivated according to the mode
set for transmitter deactivation. If the
input signal returns to the original
value within the delay time,
transmitter deactivation is ended.
1
Extended operating range
2
Reduced operating range
3
Time delay
Table 7:
Operating range
Factory settings:
T
ra
n
smi
tt
er
Pin 1
Pin 3
Description
+24 V DC
GND
Extended operating range: 1000 … 5000 mm (10000 mm for –
ER)
GND
+24 V DC
Reduced operating range: 300 … 1300 mm
3.6.2.1
Overview table of configuration values for transmitter
Default value
(value range)
Description
First beam
1
Value is always 1
Last beam
xx
Value is dependent on bar
High signal at input
3
Transmitter deactivation with active
transmitter input
Low signal at input
0
Transmitter deactivation with inactive
transmitter input
Operating range
0 or 1
(0…255)
Extended (0) or reduced (1) operating range
2…255: Disable transmitter deactivation
Synchronization beam
first
first = Synchronization using first beam
last = Synchronization using last beam
Table 8:
Configuration values for transmitter