Product description
Leuze electronic GmbH & Co. KG
CSL 505
19
3.6
Parameters (transmitter)
When the transmitter is switched off by means of an input signal, a switching operation is specifically
triggered, e.g. for a start test. Various functions are configurable.
When the transmitter is deactivated, the receiver reacts in the same way as for a beam interruption,
and the transmitter LED flashes.
The transmitter cycle is not stopped; the system is therefore quickly ready for operation again after
transmitter activation.
3.6.1
High signal or Low signal at input
Use the parameter value
High signal at input
for transmitter deactivation with active transmitter
input, or
Low signal at input
for transmitter deactivation with inactive transmitter input.
Parameter "High signal at input" or "Low signal at
input" for deactivation with signal at transmitter
input
Active
Inactive
Low
High
Low
High
Comment
0
0
0
0
Transmitter deactivation off.
0
1
1
0
Only the synchronization beam is
switched off.
The warning output remains unchanged
e.g. for a start test.
0
2
2
0
The synchronization beam remains
active; all other beams are switched off.
If the warning output is active, it
switches after
Automatic beam
blanking delay [s]
(see the section 3.5.5.3 „Autom. beam
bl. delay [s]“ on page
0
3
3
0
All beams are switched off, e.g. to
prevent interference at multiple sensors.
The warning output remains unchanged.
(Factory setting in
bold type
)
Table 6:
High signal and Low signal at input