Mounting and commissioning
Leuze electronic GmbH & Co. KG
CSL 505
23
4.1
Electrical connection
1.
Bars must only be connected while there is no voltage in the system.
2.
Avoid ground loops; all bars must have the same grounding potential.
3.
A potential difference of 60 V between the bar housing and the supply voltage must not be
exceeded.
4.
Insulate unused wires.
4.1.1
M8 connector variant
M8 terminal plug, front view
Figure 5:
M8 connector version, open cable end
Pin
Tx
Rx
1, 3
+24 V DC, GND
+24 V DC, GND
2*
n.c.
Dark switching
4
Tx_Off
Light switching
* Used for the teach event
By reversing the polarity of the supply voltages on the transmitter and receiver, it is possible to switch
between predefined device functions:
T
ra
n
smi
tt
er
Pin 1
Pin 3
Description
+24 V DC
GND
Extended operating range: 1000 … 5000 mm
GND
+24 V DC
Reduced operating range: 300 … 1300 mm
R
ec
ei
ver
Pin 1
Pin 3
Description
+24 V DC
GND
Only parallel beams
GND
+24 V DC
Parallel and diagonal beams
The depicted assignments are standard settings. The assigned functions can be freely configured.