Product description
Leuze electronic GmbH & Co. KG
CSL 505
16
3.5.12
Warn signal delay [s]
Time after which soiling is signaled. See the section 3.5.11 "Relative switching threshold: Warn" on
page 15.
Input option:
0…255
Factory setting:
60
3.5.13
Power-up teach delay [s]
Switching threshold setting is activated at power-up. After a time (in seconds) has elapsed, the
determined reference values are saved in a non-volatile memory, provided that the monitoring range
was free. Otherwise the original reference values are used. This teach event at power-up is
deactivated with "0" and "255".
Input option:
0…255
Factory setting:
0
3.5.14
Blanking warning
Blanking warning
specifies the position (beam number) as of which an error message is issued in
the event of blanking.
Input option:
0…160
Factory setting:
0