Min./max. measurement length parameter
With this parameter, a working limit on the bar code tape can be defined. The BPS 8 outputs position
values within these minimum and maximum limits. Outside of this limit, a position value of zero is output.
Measurement error tolerance parameter
The measurement error tolerance function is used to configure a time which results in an extended output
of the last position value in the event of an error. If the position value changes momentarily to zero, e.g.
due to a brief interruption of the scanning beam, soiling of the bar code tape or other short-term distur
-
bances, the BPS 8 transmits the last valid position value.
If the error disappears within the configured time, the control notices nothing. The availability of the system
is thereby ensured. No new values are delivered by the BPS 8, however, for a period of time extending up
to the configured tolerance time. With the Delay error output parameter, an integration error (corresponds
to a missing position value) can be signaled immediately or after the tolerance time has elapsed. If the
error persists after the tolerance time has elapsed, the last valid position value is output.
Position value in the case of failure parameter
Parameter
Description
Value range
Default
Unit
CR
Min. measure
-
ment length in
[mm]
Minimum permitted
measurement length.
0 … 2,147,483,647
0
mm
Switching out
-
put
,
Max. measure
-
ment length in
[mm]
Maximum permitted
measurement length.
0 … 2,147,483,647
10,000,000
mm
Switching out
-
put
,
NOTE
The switching output can be used to indicate that the measured value is outside of the mea
-
surement range. To enable this function, the "outside measurement range" or "inside mea
-
surement range" parameter must be activated.
Parameter
Description
Value range
Default
Unit
CR
Tolerance time
in [ms]
Specifies the time for the
display of the last posi
-
tion value following an
error.
0 … 65,535
50
ms
–
Delayed output
of position error
Delays the output of an
error by the configured
tolerance time.
0: No, error delay
deactivated
1: Yes, error delay acti
-
vated
1
–
–
Delayed output
of error status
Delays the output of an
error in the status byte of
the binary protocol by
the configured tolerance
time.
0: No, error delay
deactivated
1: Yes, error delay acti
-
vated
1
–
–
Parameter
Description
Value range
Default
Unit
CR
Position value
in the case of
failure
In the case of failure,
retain the last position
value or output zero.
0: Zero
1: Last valid
position value
1
–
–