Configuration / device parameters
Leuze electronic GmbH + Co. KG
BPS 8
61
Parameter
Parameter
Description
Value range
Default
Unit
CR
Digital
I/O mode
Defines whether the
switching input and out
-
put are activated via the
MA 8
-
01/MA 8
-
02 or
whether only the switch
-
ing input or only the
switching output is acti
-
vated.
0: Not released
1: BPS 8 with MA 8
-
01/
MA 8-02 (switching
input + switching
output)
2: Switching input
3: Switching output
1
–
–
Bias level /
inverted
The parameter defines
the bias level of the
switching output.
0: LOW (0V)
1: HIGH (+Ub)
0
–
–
Pulse duration
in [ms]
The parameter defines
the switch-on time
period for the switching
output. If the value is 0,
the signal is static.
0 ... 1300
400
ms
–
Switch-on func
-
tion [EF]
The parameter specifies
the events which set the
switching output:
Each
0: Not active
1: Active
–
- outside measurement
range
0
Position detec
-
tion
,
- within measurement
range
0
Position detec
-
tion
,
- erroneous measure
-
ment
1
Position detec
-
tion
- successful measure
-
ment
0
Position detec
-
tion
Switch-off func
-
tion [AF]
The parameter specifies
the events which reset
the switching output:
Each
0: Not active
1: Active
–
–
- outside measurement
range
0
Position detec
-
tion
,
- within measurement
range
0
Position detec
-
tion
,
- erroneous measure
-
ment
0
Position detec
-
tion
- successful measure
-
ment
1
Position detec
-
tion
NOTE
The events of the switch-on function and switch-off function are both linked to one another
with a logical OR.