Configuration / device parameters
Leuze electronic GmbH + Co. KG
BPS 8
53
8.5
Detailed description of the tabs
Within the tabs, the parameters are labeled alphanumerically from ... .
Example:
The parameter Preset value static [mm] is activated only if the preset teaching is carried out via switching
input .
8.5.1 Control
Figure 8.5: Control tab
Description:
The control manages the timing of the position calculation by starting and stopping the decoding. Control
is performed depending on certain events such as the switching input or time functions. Using parameters,
the events which influence the states are determined.
Parameter
NOTE
Note cross-references to parameters!
In the following detailed descriptions of the tabs you will find in the last column of the tables
cross references (CR) to parameters and input/output data of other tabs which are directly
related to the described parameter.
Pay attention to these cross-references during configuration.
a
z
a
h
Parameter
Description
Value range
Default
Unit
CR
Start mode
The start mode deter
-
mines by which event
the position measure
-
ment is started.
1: After initialization
2: Via command or
switching input
2
–
Switching input
Stop mode
The stop mode deter
-
mines after which event
the position measure
-
ment is stopped.
2: Time (Polling Inter
-
val)
3: Time with re-trigger
-
ing function (polling
interval) via com
-
mand or switching
input
4: Via command or
switching input (the
switching input must
be programmed for
this purpose)
3
–
Switching input
Maximum poll
-
ing interval
Time period after which
the scanning beam is
switched off if no polling
takes place.
0 … 65,535
10,000
ms