Display and control panel AMS 348i SSI
48
AMS 348
i
SSI
Leuze electronic GmbH + Co. KG
8.3.2
Parameter menu
Parameter handling submenu
The following functions can be called up in the
Parameter handling
submenu:
• Lock and enable parameter entry
• Set up a password
• Reset the AMS 348
i
SSI to the default settings
Additional important information on parameter handling can be found at the end of the
chapter.
PROFINET submenu
Table 8.1:
Parameter handling submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter
enable
ON/OFF
The standard setting (
OFF
) prevents unintended parameter
changes.
With parameter enable activated (
ON
), the display is inverted.
In this state, it is possible to change parameters manually. As
long as parameter enabling is activated, the AMS 348
i
is dis
-
connected from the PROFINET.
OFF
Password
Activate
password
ON/OFF
To enter a password, parameter enable must be activated.
If a password is assigned, changes to the AMS 348
i
SSI can
only be made after the password is entered.
The master password 2301 overrides the individually set
password.
OFF
Password
entry
For setting a four-digit numerical password.
Parameters to
default
By pressing the enter button
after selecting
Parameters to default
, all parameters are reset to their standard
settings without any further security prompts.
In this case, English is selected as the display language.
q~ÄÉääÉ=UKOW
molcfkbq=ëìÄãÉåì
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Activation
ON/OFF
Activates or deactivates the AMS 348
i
SSI as a PROFINET
participant.
If the AMS 348
i
SSI is deactivated as a PROFINET partici
-
pant, all subsequent participants connected via the internal
switch (BUS OUT) continue to be active.
ON