Display and control panel AMS 348i SSI
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
43
TNT
35/7-2
4V
Position value
The measured position value is displayed in the configured unit of measurement.
+87.000m
With the metric setting, the measurement value is always displayed in meters
to three decimal places.
+87.0in
With the inch setting, the measurement value is always displayed in inches to
one decimal place.
8.2.2
LED status indicators
PWR LED
Off
Device OFF
- No supply voltage
Flashing green
Power LED flashes green
- No measurement value output
- Voltage connected
- Self test running
- Initialization running
- Parameter download running
- Boot process running
Green continuous light
Power LED green
- AMS 348
i
SSI OK
- Measurement value output
- Self test successfully finished
- Device monitoring active
Red flashing
Power LED flashes red
- Device OK but warning message (ATT, TMP, LSR)
set in display
- Light beam interruption
- Plausibility error (PLB)
Red
continuous light
Power LED red
- No measurement value output; for details, see
display
Flashing orange
Power LED flashes orange
- PROFINET wave function