PROFINET interface
94
AMS 348
i
SSI
Leuze electronic GmbH + Co. KG
9.9.3.14 Module 14: Static velocity limit value 4
PROFINET module identifier
Module ID
1014
Submodule ID
1
Description
The static velocity limit value 4 function compares the current velocity with a velocity stored
in the configuration. This occurs in the configured range, which is defined by range start and
range end.
Note!
Further explanations on the Range start and Range end parameters
"Module 11: Static velocity limit value 1"
Parameter
Input data
None
Output data
None
Parameter
Description
Rel.
addr.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Switching
type
Condition for the "Velocity limit
value 4" signal, which applies to
the output (module 4/5) and the
status bit (module 16).
0.0
Bit
0: Value greater than
limit
1: Value less than limit
0
–
–
Direction
selection
Selection of the direction-depen
-
dent or direction-independent
limit value check.
0.1
Bit
0: Direction indepen
-
dent
1: Direction dependent
0
–
–
Velocity limit
value 4
Limit value is compared to the
current velocity.
1…2 unsign
16 bit
0 … 20000
0
mm/s
(in/
100)
/s
16g
Velocity
hysteresis 4
Relative shift to prevent signal
bouncing.
3…4 unsign
16 bit
0 … 20000
100
mm/s
(in/
100)
/s
–
Limit
value 4
range start
The velocity limit value is moni
-
tored beginning at this position. 5…8
sign
32 bit
-999999 … +999999
0
mm
in/
100
–
Limit
value 4
range end
The velocity limit value is moni
-
tored up to this position.
9
…
12
sign
32 bit
-999999 … +999999
0
mm
in/
100
–
Parameter length: 13 bytes
~
Ä
Å
Ç
É
Ñ