PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
65
TNT
35/7-2
4V
9.8.4.3 Step 3 – Hardware configuration of the S7 PLC: Configuration
The AMS 348
i
is activated by "Drag and Drop" and receives the IP address and a unique
device name.
Figure 9.7: Insert AMS 348
i
into the project
Double-clicking the participant opens the properties window. Here you can assign a unique
device name that exists only once in the network. If desired, an IP address can be assigned
manually (not mandatory). As the assignment of the device name takes place in offline mode,
unique assignment must take place between the MAC ID of the installed device and the
device name assigned in offline mode during the further course of configuration, see also
step 5.
Figure 9.8: Assign unique device name in the properties window