PROFINET interface
Leuze electronic GmbH + Co. KG
AMS 348
i
SSI
81
TNT
35/7-2
4V
9.9.3.5 Module 5: I/O 2 Input/Output
PROFINET module identifier
Module ID
1005
Submodule ID
1
Description
The module defines the mode of operation of the digital input/output I/O 2.
Parameter
Parameter
Description
Rel.
addr
.
Data
type
Value
Default Unit
CR to
module
Metr. Inch
Function
The parameter defines whether I/
O 2 functions as an input or as an
output.
0.0 Bit
0: Input
1: Output
1
–
5cd
Activation
The parameter defines the level of
the output at which the "Output"
event occurs. If I/O 2 is configured
as an input, the response is edge-
triggered.
0.1 Bit
0: Low
1-0 transition
1: High
0-1 transition
0
–
–
Output
The parameter defines which
event triggers activation of the
output. The individual functions
are OR-linked to one another
–
5a
Position limit value 1
If the position value is outside of
configured limit range 1, the out
-
put is set.
1.0 Bit
0 = OFF
1 = ON
0
–
Position limit value 2
If the position value is outside of
configured limit range 2, the out
-
put is set.
1.1 Bit
0 = OFF
1 = ON
0
–
Velocity limit value
If the velocity value is outside of
the configured values, the output
is set. Monitoring from modules
11 to 15 is OR-linked.
1.2 Bit
0 = OFF
1 = ON
0
–
Intensity (ATT)
If the intensity of the received sig
-
nal is less than the warning
threshold, the output is set.
1.3 Bit
0 = OFF
1 = ON
1
–
Temperature (TMP)
If the internal device temperature
exceeds the set limit value, the
output is set.
1.4 Bit
0 = OFF
1 = ON
1
–
Laser (LSR)
Laser prefailure message.
1.5 Bit
0 = OFF
1 = ON
1
–
Plausibility (PLB)
If implausible measurement val
-
ues are diagnosed, the output is
set.
1.6 Bit
0 = OFF
1 = ON
0
–
~
Ä