Device description
Leuze electronic
ODS 9
22
• Strong
• Falling on one side: 36 %
• Used center area, averaged: 28 %
Fig. 3.5:
Strong filter depth
NOTICE
In the case of dynamic applications with erratic changes in measurement distance, it is recom-
mended to filter by setting the response time.
Distance calibration "Distance correction"
Under the
Distance correction
menu item, you can influence the output of the measured distance value.
Gradient
If the gradient is changed from
rising
to
falling
, the measurement values decrease as the distance from the
object to the sensor increases. The distance information is output inverted.
NOTICE
Negative measurement values may result if the gradient is reversed.
Offset and Preset
Deviations that arise while mounting and attaching the sensor can be compensated for with the entries for
the
Offset
and
Preset
parameters.
NOTICE
Negative measurement values may occur if an
offset
is set.
The
offset/preset
calculation is available as a teach function. The assignment of the teach time frame can
be read out via IO-Link (see chapter 7 "Starting up the device").