Device description
Leuze electronic
ODS 9
16
3.4.1
Input menu
The function of the switching input on pin 5 is set in the
Input
menu.
NOTICE
The
Input
menu is only available for sensors with multifunction input on pin 5 (ODS9…/
LAK
-
…).
Level 1
Level 2
Level 3
Description
Default
Input
Input Mode
Function of the switching input on pin 5 if the supply voltage
is applied.
No Function
No input function active
Teach
Teach analog output and switching out-
put
X
Deactivation
Switch off laser transmitter with +24 V
on the switching input
Activation
Switch on laser transmitter with +24 V
on the switching input
Trigger rising The measurement value is only updated
and output by an edge on input PIN 5.
Trigger falling
Important
: Activation or deactivation using IO-Link commands or process data (PDOut) only has an effect
if neither
Deactivation
nor
Activation
is set as the input function.
3.4.2
Output_SSC1 menu
The switching behavior of switching output SSC1 is set to pin 4 in the
Output_SSC1
menu.
NOTICE
Designation "SSC" corresponds to designation "Q" previously used for switching outputs.
Level 1
Level 2
Level 3
Description
Default
Output_SSC1 SSC1_SP1_dist.
Upper switching point
Depending on the
device range:
• 100 mm: 75 mm
• 200 mm: 175 mm
• 450 mm: 250 mm
• 650 mm: 350 mm
SSC1_SP2_near
Lower switching point
50 mm
Notice
: For the limit values of the measurement range for your sensor, see chapter 12
SSC1_Hysteresis
Hysteresis
ODS9L1.8…:
10 mm
SSC1_Logic
Behavior of the switching output if an
object is within the taught/configured
switching distance.
• High active: switching output ac-
tive (high)
• Low active: switching output in-
active (low)
High active