Extended configuration – Leuze electronic webConfig tool
Leuze electronic
LSIS 472i
31
Clearing browser history
The cache of the Internet browser is to be cleared if different device types or devices with different firmware
were connected to the webConfig tool.
Delete cookies and temporary Internet and website data from the browser cache before starting the
webConfig tool.
Example for Internet Explorer 10:
Tools > Delete browsing history > [Delete]
Note limit of Firefox sessions for version 17.0 and higher
If the limited number of Firefox sessions is exceeded, it may no longer be possible to address the device
via the webConfig tool.
Do not use the refresh functions of the Internet browser:
[Shift] [F5] or [Shift] + mouse click
9.3
Short description of the webConfig tool
The menus and dialog boxes of the webConfig tool are intuitive to operate and offer help texts and tool tips.
9.3.1 Operating modes
For configurations with the webConfig tool, you can switch between the following operating modes:
•
Process
The device is connected to the control.
• The process communication to the control is activated.
• The switching inputs/outputs are activated.
• The configuration cannot be changed.
•
PROCESS
function available.
•
CONFIGURATION
function not available.
•
Service
• The process communication to the control is interrupted.
• The switching inputs/outputs are deactivated.
• The configuration can be changed.
•
PROCESS
function not available.
•
CONFIGURATION
function available.
9.3.2 Configuration via the webConfig tool
Use webConfig tool to set up the device:
Select the check program; see chapter 9.3.3.
Configure compartment fine positioning for fast commissioning; see chapter 9.3.4.
Calibrate the device; see chapter 9.3.5.
Configure the image acquisition; see chapter 9.3.6.
Define the changeover of the check programs; see chapter 9.3.9.
Configure the BLOB analysis; see chapter 9.3.7.
Configure the measurement; see chapter 9.3.8.
Configure the digital switching input/outputs; see chapter 9.3.10.
Assign measurement values to the digital switching outputs; see chapter 9.3.11.
Activate the marking display on the display; see chapter 9.3.12.
Configure the output via an FTP connection; see chapter 9.3.13.
Configure the output via an Ethernet connection; see chapter 9.3.14.