![Leuze electronic LSIS 472i M45-I1 Operating Instructions Manual Download Page 27](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019027.webp)
Commissioning
Leuze electronic
LSIS 472i
27
1
Marking indicator
Figure 8.4: Device aligned with the marking
Press the escape button
to exit
Service
mode.
If necessary, teach-in the position for fine adjustment; see chapter 8.3.
Calibrate the device for the current check program with the webConfig tool; see chapter 9.3.5 "Calibrat
ing".
8.3
Teaching-in the position
For fine adjustment and, alternatively, for exact mechanical alignment via the
Commissioning
menu, the
user can teach-in the position of the device via the display.
While teaching-in the position (teach), a position correction of the coordinate system of the capture range
is performed.
To teach the position for the current alignment, the marking (hole or reflector) must be located within the
capture range; see figure 8.3.
In
Service
mode, select
Commissioning
.
Select the distance for teaching-in (
Rack Near
or
Rack Far
).
Select the
Teach-in
menu.
Select
Teach-in
.
If the
Teach-in
menu option is crossed out in the
Teach-in
menu, teaching-in of the position is not possible.
Mechanically realign the device; see chapter 8.2 "Mechanically aligning the device via the display".
Possible causes:
• The marking is not in the capture range of the device.
• The limits of the new capture range ascertained by teaching in are not completely in the field of view.
Exit the
Commissioning
menu.
To do this, press the Escape button
.
1
ESC
Teaching-in of the position is performed separately for each distance.
Reteaching of the position is not performed for a different hole geometry or for different exposure/
focal settings.
NOTICE
Align the device before teaching-in the position!
The device must be roughly aligned before teaching-in the position.
The capture range must not exit the field of view.
For the
Rack Near
distance, the teach range is nearly zero since the field of view is almost the same
as the capture range.
Use the navigation buttons
to move through the menu. Activate the desired selection with
the enter button
.
ESC