Extended configuration – Leuze electronic webConfig tool
Leuze electronic
LSIS 472i
34
Figure 9.5:
Tool configuration – Calibration
dialog
Calibrate via the point detectors if necessary.
Enter the diameter of the marking (hole or reflector) in the selection list [Calibration block length].
Click on the [Accept values] button.
Setting the offset
For the current check program, you can set additional distances (offsets) for the positioning. By means of
the offset value, it is possible to detect, e.g., the position difference between loading position and unloading
position of the high-bay storage device.
• If the offset values are 0, the smart camera positions the high-bay storage device exactly on the
marking.
• If offset values are set, the control signals a corresponding position deviation.
Example: with offset Y = 20 mm, the high-bay storage device is positioned 20 mm below the mark
-
ing.
Select
CONFIGURATION > PROGRAMS
.
Select the active check program (
Rack Near
or
Rack Far
).
Select
CONFIGURATION > PROGRAM > Tools > Calibration > Offset
.
The
Tool configuration – Offset
dialog is displayed.
NOTICE
Recalibration required if the measurement distance changes!
If the distance for the check program (
Rack Near
or
Rack Far
) changes in the application, the calibra
-
tion must be adjusted.
The offset is not visualized in the image.