![Leuze electronic LSIS 472i M45-I1 Operating Instructions Manual Download Page 51](http://html1.mh-extra.com/html/leuze-electronic/lsis-472i-m45-i1/lsis-472i-m45-i1_operating-instructions-manual_1884019051.webp)
Technical data
Leuze electronic
LSIS 472i
51
Table 13.4:
Mechanical data
Table 13.5:
Environmental data
Device with heating
Table 13.6:
Electrical equipment
Table 13.7:
Ambient temperature
Housing
Diecast aluminum
Connection technology
M12 connectors
Degree of protection
IP 65, IP 67
Each with screwed-on M12 connector
Weight
500 g
Dimensions
(H x W x D) 113 mm x 75 mm x 55 mm
Lens cover
Glass
Ambient temperature (operation)
0 °C … +45 °C
Temperature range (storage)
-20 °C … +70 °C
Air humidity
Maximum 90 % rel. humidity, non-condensing
Vibration
IEC 60068-2-6, test Fc
Shock
Continuous shock
IEC 60068-2-27, test Ea
IEC 60068-2-29, test Eb
Electromagnetic compatibility
EN 61000-6-2, EN 61000-6-4
Operating voltage U
B
24 VDC ± 20 %
Devices with heating do not have UL approval
Power consumption
20 W maximum
Structure of the heating
Housing heating and separate heating of the optics glass
Warmup time
Minimum 30 min at +24 VDC and an ambient temperature
of -35 °C
Minimum conductor cross section
Conductor cross section of at least 0.75 mm² for the sup
-
ply voltage supply line.
Notice:
Wiring through of the voltage supply to multiple heating
devices is not permissible.
Standard, M12 ready-made cable not usable (insufficient
conductor cross section).
Ambient temperature (operation)
-35 °C … +45 °C
Temperature range (storage)
-20 °C … +70 °C