Commissioning and configuration
Leuze electronic
BCL 504
i
161
TNT 35/7-24V
Parameter length
23 byte
Input data
None
Output data
None
Remark
The DC bias level also defines whether the output is low-active (
0
) or high-active (
1
).
Switching on an I/O configured as an output means switching to the active state; switching
off, on the other hand, results in switching to the inactive or idle state.
Reset mode
(Event Coun-
ter)
Specifies whether the counter
(Event Counter) is reset only
by the reset bit and the
selected switch-off function, or
if the counter should be auto-
matically reset after the com-
parative value is reached.
12
UNSIGNED8
0: Reset bit
and switch-
off funct.
1: Compara-
tive value
reached
0
-
Mode of operation for configuration as an input
Inversion
The parameter defines the
logic of the incident signal. In
case of an inversion, an exter-
nal HIGH level is interpreted
internally as a LOW level.
13.1
Bit
0: Normal
1: Inverted
0
-
Reserved
Free
13.2 … 13.7
Debounce
time
The parameter defines a
debounce time which is imple-
mented in software.
14
UNSIGNED16
0 … 1000 5
ms
Start-up delay
The parameter influences the
timing during switch-on.
16
UNSIGNED16
0 … 65535
0
ms
Minimum
switch-on
time
The parameter defines a mini-
mum time period before the
signal is reset.
18
UNSIGNED16
0 … 65535
0
ms
Switch-off
delay
The parameter defines a time
delay for the signal during
switch-off.
20
UNSIGNED16
0 … 65535
0
ms
Input function
The parameter specifies the
function which is to be acti-
vated or deactivated by a
change of state in the signal.
22
UNSIGNED8
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.49:
Parameters for module 71 – Input/Output 2