Commissioning and configuration
Leuze electronic
BCL 504
i
143
TNT 35/7-24V
Parameter length
37 byte
Input data
None
Output data
None
Identifier string n (n = 1 … 5)
The identifier string defines both the identifier list for the segmentation and the passthrough
filter for the subsequent filtering.
The string may contain wildcards. That is, an arbitrary number of '?' are permitted as place-
holders for an arbitrary character at exactly that position.
Also permitted are '*' as placeholders for a character sequence of arbitrary length, and an 'x'
if the character at the respective position is to be deleted. There are a total of 5 identifier
strings.
An identifier with less than 5 characters must be null terminated. However, if the identifier
string consists of exactly 5 characters, it does not have to be null terminated.
Start position
of the 4th data
value
Specifies the position of the first char-
acter of the fourth data value in the
data string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
34
UNSIGNED8
0 … 127
0
-
Start position
of the 5th iden-
tifier
Specifies the position of the first char-
acter of the fifth identifier in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
35
UNSIGNED8
0 … 127
0
-
Start position
of the 5th data
value
Specifies the position of the first char-
acter of the fifth data value in the data
string of the barcode.
The first character in the barcode has
position 1. If the parameter is = 0, it is
deactivated.
36
UNSIGNED8
0 … 127
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.35:
Parameters for module 53