Electrical connection
Leuze electronic
BCL 504
i
73
TNT 35/7-24V
Described in the following is the external wiring for use as a switching input or output; the
respective function assignments to the switching inputs/outputs can be found in chapter 10.
Function as switching input
Figure 7.1:
Switching input connection diagram SWIO_3 and SWIO_4
ª
If you use a sensor with a standard M12 connector, please note the following:
• Pins 2 and 4 must not be operated as switching outputs if sensors which function as
inputs are also connected to these pins.
If, for example, the inverted sensor output is connected to pin 2, and pin 2 of the barcode
reader is, at the same time, configured as an output (and not as an input), the switching
output malfunctions.
Attention!
The maximum input current must not exceed 8mA!
Function as switching output
Figure 7.2:
Switching output connection diagram SWIO_3 / SWIO_4
Attention!
Each configured switching output is short-circuit proof! Do not load the respective switching
output of the BCL 504
i
with more than 60mA at +10 … +30VDC in normal operation!
Switching input
Switching output
from controller
(deactivated)
Switching input
to controller
Switching output
Switching output
from controller
Switching input to
controller (deacti-
vated)