Commissioning and configuration
Leuze electronic
BCL 504
i
157
TNT 35/7-24V
10.12.3 Switch-on and switch-off functions for operation as an output
The following options are available for switch-on and switch-off functions in the "output"
operating mode:
10.12.4 Input functions for operation as an input
Name
Value
Comments
No function
0
No functionality
Reading gate start
1
Reading gate end
2
Positive reference code comparison 1
3
Negative reference code comparison 1 4
Valid read result
5
Invalid read result
6
Device ready
7
The device is in a ready state
Device not ready
8
The device is not yet ready (motor and laser are being activated)
Data transmission active
9
Data transmission not active
10
AutoControl good quality
13
AutoControl bad quality
14
Reflector detected
15
Reflector not detected
16
External event, pos. edge
17
In the PROFIBUS case, the external event is generated with the aid
of module 74 – "I/O status and control". See "Module 74 – SWIO
status and control" on page 166.
External event, neg. edge
18
See above
Device active
19
Decoding is currently being performed.
Device in standby mode
20
Motor and laser inactive
No device error
21
No error was detected
Device error
22
Device is in an error state
Positive reference code comparison 2
23
Negative reference code comparison 2 24
Table 10.46:
Switch-on/switch-off functions
Name
Value
Comments
No function
0
No functionality
Activation of the reading gate
1
Reading gate deactivation only
2
Reading gate activation only
3
Reference barcode teach-in
4
Start/stop autoconfiguration mode
5
Table 10.47:
Input functions