Commissioning and configuration
Leuze electronic
BCL 504
i
131
TNT 35/7-24V
10.8.4
Module 31 – Reading gate number
Description
The module defines input data for the communication of the number of reading gates since
system start.
Parameters
None
Input data
Input data length
2 byte consistent
Output data
None
10.8.5
Module 32 – Reading gate time
Description
This module returns the time between opening and closing of the last reading gate.
Parameters
None
Input data
Input data length
2 byte consistent
Output data
None
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Reading gate
number
The BCL 504
i
transmits the cur-
rent reading gate number. The
reading gate number is initialised
with the system start and is then
incremented continuously. At
65535, an overflow occurs and
the counter starts afresh from 0.
0 … 1
UNSIGNED16
0 … 65535
0
-
Table 10.21:
Input data for module 31
Input data
Description
Addr.
Data type
Value range
Init
value
Unit
Opening duration
of the reading
gate
Opening duration of
the last reading
gate in ms.
0 … 1
UNSIGNED16
0 … 65535
If the range is exceeded, the
value remains at 65535
0
ms
Table 10.22:
Input data for module 32