Display and control panel
Leuze electronic
BCL 504
i
87
TNT 35/7-24V
Digital SWIO
The
Digital SWIO
submenu is used to configure the 4 switching inputs/outputs of the
BCL 504
i
.
Table 8.3:
Digital SWIO submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Sw. input/
output 1
I/O mode
Input / Output / Passive
Determines the function of switching
input/output 1.
In the case of passive, the connection
is on 0V if the Inverted parameter is
set to OFF, and on +UB if the Inverted
parameter is set to ON.
Input
Switching input Inverted
OFF / ON
OFF = activation of the switching input
function upon high level at the switch-
ing input
ON = activation of the switching input
function upon low level at the switch-
ing input
OFF
Debounce time
Value from 0 to 1000
Time in milliseconds for which the
input signal must be present and sta-
ble.
5
Start-up delay
Value from 0 to 65535
Time in milliseconds between the end
of the debounce time and activation of
the function configured below.
0
Pulse duration
Value from 0 to 65535
Minimum activation time in millisec-
onds for the function configured
below.
0
Switch-off delay
Value from 0 to 65535
Time in milliseconds for which the
function configured below remains
activated after the switching input sig-
nal is deactivated and the pulse dura-
tion has expired.
0
Function
No BCL500i function
Rd. gate start/stop
Rd. gate stop
Rd. gate start
Teach reference code
Autoconfig start/stop
The function set here is carried out
after the switching input is activated.
Reading gate
start/stop