PROFIBUS interface
Leuze electronic
AMS 304
i
58
TNT
35/7-2
4
V
Notice!
If the
unit of measurement is changed from metric to inch
(or vice versa),
previously
entered numerical values
(e.g. for offset, preset, limit values etc.)
are not automatically
converted
. This must be performed manually!
Example:
Preset = 10000 mm -> Change from metric to inch -> Preset = 10000 inch/100
Hex coding of the "position value" parameter
The value listed in this table shows the hex coding of the default settings:
Input data
Output data
no
Module address
Sign
Unit
Resolution
Count direction
Offset
01
10
00 00 00 00
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Position value
Output of the current position.
0
sign
32 bit
-999999 … +999999
–
scaled
9a
Input data length: 4 bytes consistently
f