PROFIBUS interface
59
AMS 304
i
Leuze electronic
9.4.3.3
Module 2: Static preset
Description
With this module, a preset value can be specified. The specified preset value becomes active
in the position in which preset teaching is performed.
Notice!
In the event of a device change the preset value is retained in the PROFIBUS manager. The
activation of the preset value (preset teach) at the intended position must, however, be
performed again.
Parameters
Hex coding of the "preset value" parameter
The value listed in this table shows the hex coding of the default settings:
Input data
no
Output data
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Preset
Preset value.
The value is accepted during a corre-
sponding teach event (see output data).
The parameter applies to all interfaces.
The resolution of the preset value is
independent of the resolution selected in
module 1.
0
sign
32 bit
-999999 … +999999
0
mm
in/100
2b
4d
5d
Parameter length: 4 bytes
a
Module address
Preset v
a
lue
02
00 00 00 00
Output data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Preset teach
Read in the preset value.
0.0
Bit
0
Æ
1 Preset teach
–
–
4d
5d
Preset reset
Preset value is deactivated.
0.1
Bit
0
Æ
1 Preset teach
–
–
4d
5d
Output data length: 1 byte
b