PROFIBUS interface
Leuze electronic
AMS 304
i
62
TNT
35/7-2
4
V
Hex coding of the "I/O 1 input/output" parameter
The value listed in this table shows the hex coding of the default settings:
Notice!
Behavior of the AMS 304
i
on Laser ON/OFF:
If the laser light spot is positioned on the reflector when the laser diode is switched on, the
AMS 304
i
returns valid measurement values after approx. 330 ms.
If the laser light spot is
not
positioned on the reflector when the laser diode is switched on,
the AMS 304
i
cannot calculate any distance values. If the laser beam hits the reflector at a
later point in time while switched-on, the AMS 304
i
200 returns valid measurement values
after the following time span:
t = (measurement distance / 20 m) sec.
Example:
Corridor change of a high-bay storage device during which the laser diode
is not switched off while travelling around curves.
Measurement distance 100 m –> t = 5 sec., measurement distance
200 m –> t = 10 sec.