Device parameters and interfaces
Leuze electronic
AMS 200
87
TNT
3
5/7-2
4
V
Notice
!
For connecting
BUS IN
and
BUS OUT
we recommend our ready-made Interbus cables (see
chapter 10.8 "Accessory ready-made cables for interface connection" on page 10
).
Attention
!
The laser measurement system can be used to branch out the Interbus network. The
con-
tinuing network
is connected via
BUS OUT
.
The integrated SUPI (Serial Universal Peripheral Interface) automatically detects whether
additional participants are connected to BUS OUT. Termination of BUS OUT is not neces-
sary.
8
.
3
.4.2
Shielding and grounding concept
The cable shielding must be concentric and have the largest possible surface area on the
M 12 connector (thread).
The M 12 thread for BUS IN is connected to the functional earth (FE) inside the AMS 200 via
an RC element (1M
Ω
|| 15nF).
The M 12 thread for BUS OUT is conductively connected to the housing and is thus directly
connected to the functional earth (FE).
8
.
3
.4.
3
PWR connection
Figure 8.14: Interbus - electrical connection PWR
PWR
I/O 2
I/O 1
3
2
1
4
5
GND
VIN
FE
M 12-plug
(A-coded)
PWR (5-pin plug, A-coded)
Pin
Name
Remarks
1
VIN
Positive supply v18 … +
3
0 V DC
2
I/O 1
Input/output 1,
by default:
Input
:
low (0 V) = laser on,
high (VIN) = laser off
3
GND
Supply voltage 0 V DC
4
I/O 2
Input/output 2,
by default:
Output
:
low (0 V) = velocity limit value exceeded
high (VIN) = below velocity limit value
5
FE
Functional earth
Thread
FE
Functional earth (housing)