Control panel display AMS 200…
24
AMS 200
Leuze electronic
6.2.2
Status displays
6.2.2.1
LED PWR
off
device OFF
- no supply voltage
flashes green
device ok, initialisation phase
- no measurement value output
- voltage connected
- self test running
- initialisation running
- parameter download running
- booting
green
continuous light
device ok
- measurement value output
- self test successfully finished
- device monitoring active
flashes red
device ok, warning set
- measurement value output
- light beam interruption detected
- plausibility error detected
red
continuous light
device error
- no measurement value output
- for details see status displays on the display
6.2.2.2
BUS LED (for PROFIBUS only; no function for Interbus)
off
no supply voltage
- PROFIBUS deactivated (SSI interface only)
green continuous light
bus ok
- device active on PROFIBUS ("data exchange")
flashes red
bus error
- configuration failed ("parameter failure")
- DP error
- no data exchange
red continuous light
bus error
- no DP protocol established to the master ("no data
exchange")