Specifications
Leuze electronic
AMS 200
17
TNT
3
5/7-2
4
V
4.
3
.4
BUS IN - (Interbus)
I
NTERBUS
:
4.
3
.5
BUS OUT - (Interbus)
I
NTERBUS
:
4.
3
.6
SSI interface
SSI
BUS IN (5-pin plug, B-coded)
Pin
Name
Remarks
1
DO
From the Interbus master
2
/DO
From the Interbus master - inverted
3
DI
To the Interbus master
4
/DI
To the Interbus master - inverted
5
Data GND
Data Ground
Thread
SHIELD
Shield via RC element on the housing
BUS IN
DI 3
2
1
4
Data
GND
/DO
/DI
DO
5
M 12 plug
(B-coded)
BUS OUT (5-pin socket, B-coded)
Pin
Name
Remarks
1
DO
From the Interbus master
2
/DO
From the Interbus master - inverted
3
DI
To the Interbus master
4
/DI
To the Interbus master - inverted
5
Data GND
Data Ground
Thread
SHIELD
Shield directly on the housing
BUS OUT
DO 1
2
3
4
/DO
/DI
DI
Data
GND
5
M 12 socket
(B-coded)
SSI (5-pin plug, B-coded)
Pin
Name
Remarks
1
DATA+
+
Data line SSI (output)
2
DATA-
-
Data line SSI (output)
3
CLK+
+
Clock line SSI
(input electrically insulated)
4
CLK-
-
Clock line SSI
(input electrically insulated)
5
FE
Functional earth
Thread
FE
Functional earth (housing)
SSI
CLK+ 3
2
1
4
FE
DATA-
CLK-
DATA+
5
M 12 plug
(B-coded)