Device parameters and interfaces
Leuze electronic
AMS 200
77
TNT
3
5/7-2
4
V
Hex coding of the "SSI interface" parameter
The value listed in this table shows the hex coding of the default settings:
Input data
none
Output data
none
Notice
!
Resolution and maximum position value which can be represented:
Table 8.5:
SSI interface - resolution and maximum position value which can be
represented
Modul
e ad
dress
Codi
ng
Mode
Res
o
lutio
n
Update rate
Er
ro
r bi
ts
11
19
61
SSI setting
Max. distance which can be
represented
Metric
Max. distance which can be
represented
Inches (in)
24-bit; resolution 0.1
1,677 m
16,777 in
≈
426 m
24-bit; resolution 0.01
167 m
1,677 in
≈
42 m
24-bit; resolution 0.001
16 m
167 in
≈
4 m
25-bit; resolution 0.1
3
,
3
55 m
33
,554 in
≈
852 m
25-bit; resolution 0.01
33
5 m
3
,
3
55 in
≈
85 m
25-bit; resolution 0.001
33
m
33
5 in
≈
8 m
26-bit; resolution 0.1
6,710 m
67,108 in
≈
1,704 m
26-bit; resolution 0.01
671 m
6,710 in
≈
170 m
26-bit; resolution 0.001
67 m
671 in
≈
17 m