Mounting
3
4
AMS 200
Leuze electronic
7.
3
Mounting with deflector unit
7.
3
.1
General information
The two available deflector units are used for the 90 ° deflection of the laser beam,
see "Accessory deflector unit" on page 101.
Attention
!
The deflector units are designed for a maximum range of 40 m.
Longer distances on request.
7.
3
.2
Mounting the US AMS 01 deflector unit with integrated mounting bracket
For this purpose the laser measurement system is screwed onto the body of the US AMS 01
deflector unit. For stand mounting the mirror can be mounted for
3
different directions of
deflection:
1.
Upward beam deflection
2.
Beam deflection to the left
3
.
Beam deflection to the right
The deflector unit is mounted on plane-parallel, flat and vertical walls or plant components.
For error-free position measurement there must be unobstructed line of sight between the
AMS 200… and the deflection mirror as well as between the mirror and the reflector.
Use the M5 screws to mount the deflector unit. Secure the screws with a toothed lock
washer to protect against loosening caused by vibrations.
Figure 7.4: Mounting variants of the US AMS 01 deflector unit
Summary of Contents for AMS 200