Device parameters and interfaces
Leuze electronic
AMS 200
59
TNT
3
5/7-2
4
V
8
.1.6.
8
Module
8
: Position limit value range 2
Description
The position limit value range 2 parameter defines a distance range with lower and upper
limits. If the measured value lies outside of the configured range, the corresponding bit is set
in module 6 or, if configured, an output is set.
Parameter
Hex code of the "position limit value range 2" parameter
The value listed in this table shows the hex coding of the default settings:
Input data
none
Output data
none
Parameter
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr. inch
Lower pos.
limit 2
Specifies the lower position
limit.
0…
3
sign
3
2 bit
-999999 … +999999
0
mm
in/
100
–
Upper pos.
limit 2
Specifies the upper position
limit.
4 …
7
sign
3
2 bit
-999999 … +999999
0
mm
in/
100
–
Parameter length:
8
bytes
a
b
Module a
d
d
res
s
Lo
w
e
r
pos.
li
mi
t 2
Upper
pos
.
lim
it
2
0
8
00 00 00 00
00 00 00 00