8
DeviceNet communication
8.5
Parameterising the counter
439
Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9
Signal evaluation
counter 1
Bit 2 ... 0: Signal evaluation
• 0b000 = counter deactivated (the other parameter data
details for the counter are ignored)
• 0b001 = rotary transducer 1-fold (connection to "A/pulse"
input)
• 0b010 = rotary transducer 2-fold (connection to "A/pulse"
input)
• 0b011 = rotary transducer 4-fold (connection to "A/pulse"
input and "B/direction")
• 0b100 = direction (pulse at "A/pulse" input and direction
at "B/direction" input)
Bit 6 ... 3: Reserved
Bit 7: Gate function (internal gate)
• 0= abort (counting process starts again from loading
value)
• 1 = interrupt (counting process is continued with counter
content)
0x00
10
Set value counter 1
When a set value is given, the counter can be loaded with the
set value. With an edge 0-1 at COUNTERVAL_SET in the
control word, the set value is accepted in the counter.
0x00
11
Final value counter 1 Upper limitation of the counting range
0x00
12
Loading value
counter 1
Lower limitation of the counting range
0x00
13
Hysteresis counter 1 The hysteresis for instance serves to avoid frequent
switching operations of the output and/or triggering of the
alarm when the count value is within the range of the
comparison value. For the hysteresis you can select a range
between 0 and 255. With the settings 0 and 1 the hysteresis
is switched off.
The hysteresis has an effect on the zero crossing,
comparison, overflow/underflow.
0x00
14
Reserved
15
Alarm response
counter 2
See counter 1
0x00
16
Counter function
counter 2
See counter 1
0x00
17
Comparator
counter 2
See counter 1
0x00
18
Signal evaluation
counter 2
See counter 1
0x00
19
Set value counter 2
See counter 1
0x00
20
Final value counter 2 See counter 1
0x00
21
Loading value
counter 2
See counter 1
0x00
22
Hysteresis counter 2 See counter 1
0x00
Position in
string
Name
Description/value
Lenze
No.