Lenze · I/O system 1000 · Reference Manual · DMS 5.0 EN · 09/2016 · TD17
140
5
CANopen communication
5.10
Parameterising the counter
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Parameter data
Index/subindex
Name
Description/value
Lenze
I-3100/x
Diagnostics
A diagnostic alarm occurs if the same event triggers a further
process alarm during a process alarm processing.
Bit 5 ... 0: Reserved
Bit 6: Diagnostic alarm(0 = inhibited; 1 = enabled)
Bit 7: Reserved
0x00
I-3101/x
Input frequency
Track A
Filters for instance serve to filter signal peaks in the case of
an unclean input signal.
0 (0x00): 500 kHz
1 (0x01): 300 kHz
2 (0x02): 100 kHz
3 (0x03): 60 kHz
4 (0x04): 30 kHz
6 (0x06): 10 kHz
7 (0x07): 5 kHz
8 (0x08): 2 kHz
9 (0x09): 1 kHz
Other values are not permissible!
0x02
I-3102/x
Input frequency
Track B
0x02
I-3103/x
Input frequency
Latch
0x02
I-3104/x
Input frequency
Gate
0x02
I-3105/x
Input frequency
Reset
0x00
I-3106/x
Reserved
I-3107/x
Alarm response
Setting activates process alarm
Bit 0: Proc. alarm HW gate open
Bit 1: Proc. alarm HW gate closed
Bit 2: Proc. alarm overflow
Bit 3: Proc. alarm underflow
Bit 4: Proc. alarm comparison value
Bit 5: Proc. alarm final value
Bit 6: Proc. alarm latch value
Bit 7: Reserved
0x80
I-3108/x
Numerator function Bit 5 ... 0:
0b000000 = continuous counting
0b000001 = single counting, main counting direction is
forward
0b000010 = single counting, main counting direction is
backward
0b000100 = single counting, no main counting direction
0b001000 = periodic counting, main counting direction is
forward
0b010000 = periodic counting, main counting direction is
backward
0b100000 = periodic counting, no main counting direction
Bit 7 ... 6: Reserved
0x40
I-3109/x
Comparator
Bit 2 ... 0: output switches (... if condition is met)
0b000 = never
0b001 = count value
comparison value
0b010 = count value
comparison value
0b100 = count value = comparison value
Bit 3: Invert counting direction track B
0 = no (do not invert)
1 = yes (invert)
Bit 6 ... 4: Reset
0b000 = deactivated
0b001 = HIGH level
0b011 = rising edge
0b101 = one-time rising edge
Bit 7: Reserved
0x00