S94P01C -e1
53
Display Description
StAt
current drive status -
to view:
run
- drive running
diS
- drive disabled
F
XX - drive fault. Where XX is the fault code (section 7.3.2)
H
x.xx
Hardware revision (e.g. H2.00)
F
x.xx
Firmware revision (e.g. F2.06)
bAUd
RS232/RS485(normal mode) baud rate -
to set
selects from 2400 to 115200 baudrates
Adr
Drive’s address -
to set
sets 0 - 31 drive’s address
FLtS
Stored fault’s history -
to view
scroll through stored faults F0XX to F7XX, where XX is the fault code (section
7.3.2)
Ht
Heatsink temperature -
to view
Shows heatsink temperature in ºC if greater than 40ºC. Otherwise shows “LO” (low).
EnC
Encoder activity -
to view
Shows primary encoder counts for encoder diagnostics activity
HALL
Displays motor’s hall sensor states -
to view
Shows motor hall states in form XXX , where X is 1 or 0 - sensor logic states.
buS
Displays drive DC bus voltage -
to view
Shows DC bus voltage value
Curr
Displays motor’s phase current (RMS)
Shows current value if drive is enabled, otherwise shows “
DiS
”
CAnb
CAN Baudrate
CAnA
CAN Address
CAno
CAN Operational Mode
CAnd
CAN Delay
CAnE
CAN Enable/disable
dHCP
Ehternet DHCP Configuration: 0=”dHCP” is disabled; 1=”dHCP is enabled.
IP 4
IP Adress Octet 4
IP 3
IP Adress Octet 3
IP 2
IP Adress Octet 2
IP 1
IP Adress Octet 1