System bus (CAN) with Servo PLC & Drive PLC
Configuration (FIF interface)
5-7
l
PLC-Systembus EN 1.1
5.8
Reset node
Changes in the CAN baud rate, the node addresses and the identifiers are only accepted after a reset
node.
A reset node can be initiated by
•
a fresh power-on
•
a reset node command through an NMT command
•
a reset node command via the SB
FIF_CAN_Management
•
a reset node via C2458:
Code
LCD
Possible settings
Info
Lenze Choice
C2458 Reset node
0
0
no function
1
FIF CAN reset node
Reset node FIF CAN
5.9
System bus management
With the
FIF_CAN_Management
SB you can
•
activate a reset node
•
process a “ communication error” and “ bus off state” in the PLC program
•
influence the transmission time of FIF-CAN2_OUT and FIF-CAN3_OUT.
Tip!
Detailed information about the
CAN_Management
can be found in chapter 7.4.
Show/Hide Bookmarks