To connect the cables, do the following:
1. Use the 700 mm (27.56 inches) mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
1
to the port 0 on the RAID card. Then, connect the mini-SAS connector
2
to the mini-SAS signal
cable connector on the 3.5-inch hot-swap hard disk drive backplane.
2. Use the 2-pin 200 mm (7.87 inches) RAID card to system board hard disk drive LED cable. Connect the
end
4
to the external connector on the RAID card and the end
3
to the hard disk drive LED connector
on the system board.
Figure 26. Connecting cables for server models with one 3.5-inch hot-swap hard disk drive backplane and a RAID card
For connector location information about the RAID card, hot-swap hard disk drive backplane, and the
system board, refer to the related topics in “Locations” on page 13.
For information about connecting the appropriate power connector of the power supply to the backplane,
see “Hot-swap hard disk drive backplane” on page 34.
System board components
Your server system board is a six-layer micro-ATX board based on the Intel Bromolow platform. The
following illustration shows the component locations on the system board.
42
ThinkServer User Guide
Summary of Contents for ThinkServer
Page 1: ...ThinkServer User Guide Machine Types 0387 0388 0389 0390 0391 0392 0393 and 0441 ...
Page 16: ...4 ThinkServer User Guide ...
Page 18: ...6 ThinkServer User Guide ...
Page 64: ...52 ThinkServer User Guide ...
Page 178: ...166 ThinkServer User Guide ...
Page 186: ...174 ThinkServer User Guide ...
Page 190: ...178 ThinkServer User Guide ...
Page 208: ...196 ThinkServer User Guide ...
Page 209: ......
Page 210: ......