Diagnostic Error Code
FRU/Action
025-027-XXX
IDE interface Configuration/Setup error
1.
IDE signal cable
2. Flash the system. See “Flash update procedures”
on page 179
3. Reseat IDE signal cable
4. IDE device
5. System board
025-02X-XXX 025-03X-XXX 025-04X-XXX
IDE Interface
failure
1.
IDE signal cable
2. Check power supply
3. Reseat IDE signal cable
4. IDE device
5. System board
025-195-XXX
IDE interface Test aborted by user
Information only
Re-start the test, if necessary
025-196-XXX
IDE interface test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
025-197-XXX
IDE interface test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
025-198-XXX
IDE interface test aborted
1.
If a component is called out, make sure it is
connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Go to “Undetermined problems” on page 63
025-199-XXX
IDE interface test failed, cause unknown
1. Go to “Undetermined problems” on page 63
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Replace component under function test
030-000-XXX
SCSI interface Test Passed
No action
030-00X-XXX 030-01X-XXX
SCSI interface failure
1.
SCSI signal cable
2. Check power supply
3. SCSI device
4. SCSI adapter card, if installed
5. System board
030-027-XXX
SCSI interface Configuration/Setup error
1.
SCSI signal cable
2. Flash the system. See “Flash update procedures”
on page 179
3. SCSI device
4. SCSI adapter card, if installed
5. System board
52
ThinkCentre Hardware Maintenance Manual
Summary of Contents for ThinkCentre A70z ALL-IN-ONE
Page 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Page 2: ......
Page 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Page 188: ...182 ThinkCentre Hardware Maintenance Manual ...
Page 192: ...186 ThinkCentre Hardware Maintenance Manual ...
Page 193: ......
Page 194: ...Part Number 71Y7087 Printed in USA 1P P N 71Y7087 71Y7087 ...