Diagnostic Error Code
FRU/Action
014-196-XXX
Parallel port test halt, error threshold
exceeded
1.
Press F3 to review the log file
2. Re-start the test to reset the log file
014-197-XXX
Parallel port test warning
1.
Make sure the component that is called out
is connected and/or enabled. See Chapter 6
“Diagnostics, Test and Recovery Information” on
page 37
2. Re-run test
3. Replace the component that is called out in warning
statement
4. Replace the component under test
014-198-XXX
Parallel port test aborted
1.
If a component is called out, make sure it is
connected and/or enabled
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Go to “Undetermined problems” on page 63
014-199-XXX
Parallel port test failed, cause unknown
1. Go to “Undetermined problems” on page 63
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Replace component under function test
014-2XX-XXX 014-3XX-XXX
Parallel port failure
1.
External parallel device
2. System board
015-000-XXX
USB port Interface Test Passed
No action
015-001-XXX
USB port Presence
1.
Remove USB device(s) and re-test
2. System board
015-002-XXX
USB port Timeout
1.
Remove USB device(s) and re-test
2. System board
015-015-XXX
USB port External Loopback failure
1.
Remove USB device(s) and re-test
2. System board
015-027-XXX
USB port Configuration/Setup error
1.
Flash the system. See “Flash update procedures”
on page 179
2. System board
015-032-XXX
USB port Device Controller failure
System board
015-034-XXX
USB port buffer allocation failure
1.
Reboot the system
2. Flash the system and re-test. See “Flash update
procedures” on page 179
3. Run memory test
4. System board
015-035-XXX
USB port Reset condition detected
1.
Remove USB device(s) and re-test
2. System board
015-036-XXX
USB port Register error
System board
015-040-XXX
USB port IRQ failure
1.
Run setup and check for conflicts
2. Flash the system. See “Flash update procedures”
on page 179
3. System board
Chapter 7
.
Symptom-to-FRU Index
49
Summary of Contents for ThinkCentre A70z ALL-IN-ONE
Page 1: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Page 2: ......
Page 3: ...ThinkCentre Hardware Maintenance Manual Machine Types 0401 0421 0994 1165 1184 1186 and 2565 ...
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 46: ...40 ThinkCentre Hardware Maintenance Manual ...
Page 188: ...182 ThinkCentre Hardware Maintenance Manual ...
Page 192: ...186 ThinkCentre Hardware Maintenance Manual ...
Page 193: ......
Page 194: ...Part Number 71Y7087 Printed in USA 1P P N 71Y7087 71Y7087 ...