5. Remove the three screws (
2
,
3
and
4
) that secure the PS2 COM Port, and then disconnect the PS2
COM Port cable from the system board. Lift the PS2 COM Port out of the computer.
Figure 24. Removing the PS2 COM Port
6. Remove the two screws
1
that secure the PS2 Port. Then get the PS2 Port out of the PS2 COM Port.
7. To install a new PS2 port, install the two screws
1
that secure the PS2 Port to the PS2 COM Port.
8. To install a new PS2 COM Port into the computer, position the new PS2 COM Port into place, and then
align the screw holes with the corresponding holes in the computer main bracket.
9. Install the three screws (
2
,
3
and
4
) that secure the PS2 COM Port to the computer main bracket.
10. Connect the PS2 COM Port cable to the system board.
11. Go to “Completing the parts replacement” on page 113.
Installing or replacing a memory module
Attention:
Do not open your computer or attempt any repair before reading and understanding the “Important safety information”
in the
ThinkCentre Safety and Warranty Guide
that came with your computer. To obtain a copy of the
ThinkCentre
Safety and Warranty Guide
, go to:
http://www.lenovo.com/support
This section provides instructions on how to install or replace a memory module.
Your computer has two memory slots for installing or replacing DDR3 SDRAM DIMMs (small outline dual
inline memory modules). When installing or replacing a memory module, use 1 GB, 2 GB or 4 GB DDR3
SDRAM DIMMs in any combination up to a maximum of 8 GB of system memory.
To install or replace a memory module, do the following:
1. Remove all media from the drives and turn off all attached devices and the computer. Then, disconnect
all power cords from electrical outlets and disconnect all cables that are connected to the computer.
Chapter 8
.
Replacing FRUs
93
Summary of Contents for ThinkCentre 7570
Page 2: ......
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Page 202: ...196 ThinkCentre Hardware Maintenance Manual ...
Page 207: ......
Page 208: ...Part Number 0A22568 Printed in USA 1P P N 0A22568 0A22568 ...