Diagnostic Error Code
FRU/Action
005-2XX-XXX 005-3XX-XXX
Video subsystem error
1. Video card, if installed
2. System board
006-000-XXX
Diskette interface Test Passed
No action
006-0XX-XXX
Diskette interface error
1. Diskette drive Cable
2. Diskette drive
3. System board
006-195-XXX
Diskette interface Test aborted by user
Information only Restart the test, if necessary
006-196-XXX
Diskette interface test halt, error threshold
exceeded
1. Press F3 to review the log file.
2. Restart the test to reset the log file.
006-197-XXX
Diskette interface test warning
1. If a component is called out, make sure it is
connected and/or enabled.
2. Re-run test.
3. Replace the component that is called out in warning
statement.
4. Replace the component under test.
006-198-XXX
Diskette interface test aborted
1. If a component is called out, make sure it is
connected and/or enabled.
2. Flash the system and re-test. See “Flash update
procedures” on page 193.
3. Go to “Undetermined problems” on page 64.
006-199-XXX
Diskette interface test failed, cause unknown
1. Go to “Undetermined problems” on page 64.
2. Flash the system and re-test.
3. Replace component under function test.
006-25X-XXX
Diskette interface Error
1. Diskette drive cable
2. Diskette drive
3. System board
011-000-XXX
Serial port Interface Test Passed
No action
011-001-XXX
Serial port Presence
1. Remove external serial device, if present.
2. Run the Setup Utility program, enable port.
3. System board
011-002-XXX 011-003-XXX
Serial port Timeout/Parity
error
System board
011-013-XXX 011-014-XXX
Serial port Control
Signal/Loopback test failure
System board
011-015-XXX
Serial port External Loopback failure
1. Wrap plug
2. System board
011-027-XXX
Serial port Configuration/Setup error
1. run the Setup Utility program, enable port
2. Flash the system. See “Flash update procedures”
on page 193.
3. System board
011-03X-XXX 011-04X-XXX
Serial port failure
System board
011-195-XXX
Serial port Test aborted by user
Information only Restart the test, if necessary.
Chapter 7
.
Symptom-to-FRU Index
49
Summary of Contents for ThinkCentre 7570
Page 2: ......
Page 15: ...Chapter 2 Safety information 9 ...
Page 19: ...Chapter 2 Safety information 13 ...
Page 20: ...1 2 14 ThinkCentre Hardware Maintenance Manual ...
Page 21: ...Chapter 2 Safety information 15 ...
Page 27: ...Chapter 2 Safety information 21 ...
Page 31: ...Chapter 2 Safety information 25 ...
Page 38: ...32 ThinkCentre Hardware Maintenance Manual ...
Page 202: ...196 ThinkCentre Hardware Maintenance Manual ...
Page 207: ......
Page 208: ...Part Number 0A22568 Printed in USA 1P P N 0A22568 0A22568 ...