TP − 3 to 5 Ton High−Efficiency, R−410A Heat Pump
/ Page 2
FEATURES
CONTENTS
ARI Rating Tables
Pages 9−17
. . . . . . . . . . . . . . . . . . . . . . .
Commercial Control Systems
Page 5
. . . . . . . . . . . . . . . . .
Dimensions
Page 8
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Data
Page 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features
Page 2
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Guide Specifications
Pages 18−22
. . . . . . . . . . . . . . . . . . . .
Indoor Coil/Air Handler Substitution
Page 9
. . . . . . . . . . . .
Installation Clearances
Page 7
. . . . . . . . . . . . . . . . . . . . . . .
Model Number Identification
Page 1
. . . . . . . . . . . . . . . . . .
Optional Accessories
Page 6
. . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Sound Data
Page 7
. . . . . . . . . . . . . . . . . . . . . . . . .
Specifications
Page 6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty
Compressor
− limited warranty for
five years
.
All other covered components
−
one year
.
Refer to Lennox Equipment Limited Warranty certificate
included with unit for specific details.
Approvals
Certified in Accordance with the USE certification
program, which is based on ARI Standard 210/240−2005.
Sound rated in Lennox reverberant sound test room in
Accordance with test conditions included in ARI Standard
270-95.
Tested in the Lennox Research Laboratory environmental
test room.
Rated According to U.S. Department of Energy (DOE)
test procedures.
Units and components within bonded for grounding to
meet safety standards for servicing required by UL, NEC
and CEC.
Units are UL and ULC listed.
ISO 9001 Registered Manufacturing Quality System.
E
NERGY
S
TAR
® certified units are designed to use less
energy, help save money on utility bills, and help protect
the environment.
Applications
SEER up to 15.0.
Heating COP up to 4.04.
HSPF (Region IV) 9.0.
3 through 5 tons.
Three−phase power supply.
Vertical air discharge allows concealment behind shrubs
at grade level or out of sight on a roof.
Designed for applications with remotely located indoor air
handler units.
See Air Handlers sections for indoor unit data.
Units shipped completely factory assembled, piped and
wired. Each unit is test operated at the factory insuring
proper operation.
Installer must set outdoor unit, connect refrigerant lines
and make electrical connections to complete job.
For expanded ratings, see
www.lennoxcommercial.com
.
B
C
D
E F
G
H
I
J
REFRIGERATION SYSTEM
Refrigerant
Non−chlorine, ozone friendly, R−410A.
Unit is factory pre−charged with refrigerant. Total system
refrigerant charge is dependant on outdoor unit size,
indoor unit size and refrigerant line length.
Refer to Installation Instructions for "
Indoor Unit Match−Up
and Sub−Cooling Charge Levels
" to determine correct
amount of charge required.
Outdoor Coil Fan
Direct drive fan moves large air volumes uniformly
through entire outdoor coil for high refrigerant cooling and
heating capacity.
Vertical air discharge minimizes operating sounds and
eliminates damage to lawn and shrubs.
Fan motor has sleeve bearings and is inherently
protected.
Motor totally enclosed for maximum protection from
weather, dust and corrosion.
Rain shield on motor provides additional protection from
moisture.
Louvered steel top fan guard furnished as standard.
Fan service access accomplished by removal of top
panel.
B
Summary of Contents for TPA036H4